Remote-access Guide

2018 emergency remote access

by Ms. Mylene Feest Published 2 years ago Updated 1 year ago
image

What is an emergency power system?

The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702.

What is the size of an emergency escape and rescue opening?

Emergency escape and rescue openings shall have the bottom of the clear opening not greater than 44 inches (1118 mm) measured from the floor. 1030.4Window wells. An emergency escape and rescue opening with a finished sill height below the adjacent ground level shall be provided with a window well in accordance with Sections 1030.4.1 and 1030.4.2.

Where are aerial fire apparatus access roads required?

D105.1Where required. Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet (9144 mm), approved aerial fire apparatus access roads shall be provided.

Where are the signs for assisted rescue located?

Additionally, visual characters, raised character and braille signage complying with ICC A117.1 shall be located at each door to an area of refuge and exterior area for assisted rescue in accordance with Section 1013.4. 1009.10Directional signage. 1.

What percentage of the exterior of an assisted rescue unit is open?

How long does an emergency power system last?

What is egress protection?

Where two exit access stairways or ramps provide the required means of egress to exits at another story?

What section of the International Fire Code is required for fire evacuation?

How many stories above a level of exit discharge?

How many exits are required for a doorway?

See more

image

International Building Code 2018 (IBC 2018) | UpCodes

The International Building Code 2018 (IBC 2018) is a model code produced by the International Code Council (ICC). This document provides the foundation for many state and city codes.

Railing IBC Code Cheat Sheet

Railing IBC Code Cheat Sheet Guardrail 1. IBC 1015.2: Guards shall be located along open sided walking surfaces that are located more than 30” measured vertically to the floor or grade below at any point. 2. IBC 1015.3: Required Guards shall be not less than 42” high with the exception of occupancies not more than three stories above grade within individual dwelling / single family units which

Important Changes to the 2018 IBC for R-2 (Apartments) Approved Items 1-53

11 G24-15 503.1.4 Occupied roofs Major Change Decrease Occupied Roof. This is a major change for defining and classifying the appropriate use of an occupied roofs. These provisions outline the occupant loads, acceptable

Life Safety - Means of Egress/Exits NFPA 101

3 Means of egress components Doors, stairs, ramps, and exit passageways are the most common means of egress components. The code also permits fire escape, ladder, alternating tread devices, and slide escapes in certain occupancies.

What percentage of the exterior of an assisted rescue unit is open?

The exterior area for assisted rescue shall be open to the outside air. The sides other than the separation walls shall be not less than 50 percent open, and the open area shall be distributed so as to minimize the accumulation of smoke or toxic gases.

How long does an emergency power system last?

The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702.

What is egress protection?

The means of egress protection requirements work in coordination with other sections of the code, such as protection of vertical openings (see Chapter 7), interior finish (see Chapter 8), fire suppression and detection systems (see Chapter 9) and numerous others, all having an impact on life safety.

Where two exit access stairways or ramps provide the required means of egress to exits at another story?

Where two exit access stairways or ramps provide the required means of egress to exits at another story, the required separation distance shall be maintained for all portions of such exit access stairways or ramps.

What section of the International Fire Code is required for fire evacuation?

Such fire safety and evacuation plans shall comply with the applicable provisions of Sections 401.2 and 404 of the International Fire Code.

How many stories above a level of exit discharge?

In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator complying with Section 1009.4.

How many exits are required for a doorway?

Where access to three or more exits is required, not less than two exit or exit access doorways shall be arranged in accordance with the provisions of Section 1007.1.1. Additional required exit or exit access doorways shall be arranged a reasonable distance apart so that if one becomes blocked, the others will be available.

How far from a building is an aerial fire apparatus access road?

One or more of the required access routes meeting this condition shall be located not less than 15 feet (4572 mm) and not greater than 30 feet (9144 mm) from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official.

How wide is a dead end fire apparatus access road?

Dead-end fire apparatus access roads in excess of 150 feet (45 720 mm) shall be provided with width and turnaround provisions in accordance with Table D103.4.

How many fire apparatus roads are required for a two family dwelling?

Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads.

How many dwelling units are required for a multifamily project?

Multiple-family residential projects having more than 100 dwelling units shall be equipped throughout with two separate and approved fire apparatus access roads.

How many fire apparatuses are allowed in a 30 foot building?

Buildings or facilities exceeding 30 feet (9144 mm) or three stories in height shall have not fewer than two means of fire apparatus access for each structure.

Can power lines be located over fire apparatus?

Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be placed with the approval of the fire code official.

SAFETY AND SECURITY

A medical emergency? A roadside accident? When you encounter trouble on the road, simply press the SOS button ( Disclosure 3) in your vehicle and SiriusXM Guardian™ ( Disclosure 1) will help connect you to a local emergency services provider.

CONVENIENCE

Access the features of SiriusXM Guardian™ ( Disclosure 1) through the convenient Uconnect ® App, which lets you use your smartphone or smartwatch to keep in touch with your vehicle from a distance.

4G WI-FI HOTSPOT

lets your passengers stream, browse, share and more from the open road on up to eight devices. A 3-month trial (including 1 GB of data) is available on most new vehicles.

What percentage of the exterior of an assisted rescue unit is open?

The exterior area for assisted rescue shall be open to the outside air. The sides other than the separation walls shall be not less than 50 percent open, and the open area shall be distributed so as to minimize the accumulation of smoke or toxic gases.

How long does an emergency power system last?

The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702.

What is egress protection?

The means of egress protection requirements work in coordination with other sections of the code, such as protection of vertical openings (see Chapter 7), interior finish (see Chapter 8), fire suppression and detection systems (see Chapter 9) and numerous others, all having an impact on life safety.

Where two exit access stairways or ramps provide the required means of egress to exits at another story?

Where two exit access stairways or ramps provide the required means of egress to exits at another story, the required separation distance shall be maintained for all portions of such exit access stairways or ramps.

What section of the International Fire Code is required for fire evacuation?

Such fire safety and evacuation plans shall comply with the applicable provisions of Sections 401.2 and 404 of the International Fire Code.

How many stories above a level of exit discharge?

In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator complying with Section 1009.4.

How many exits are required for a doorway?

Where access to three or more exits is required, not less than two exit or exit access doorways shall be arranged in accordance with the provisions of Section 1007.1.1. Additional required exit or exit access doorways shall be arranged a reasonable distance apart so that if one becomes blocked, the others will be available.

image
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9