Remote-access Guide

cmore remote access setup

by Carlee Kovacek Published 1 year ago Updated 1 year ago
image

Enable Remote Access On the C-more programming software call up the Panel Network by using the main menu | Setup | Panel Network… You could also select the panel network under Setup in the Function tab of the Navigation window. Select the Remote Access on the left-hand side of the Panel Network window.

Full Answer

How do I enable remote access on C-More?

Enable Remote Access On the C-more programming software call up the Panel Network by using the main menu | Setup | Panel Network… You could also select the panel network under Setup in the Function tab of the Navigation window. Select the Remote Access on the left-hand side of the Panel Network window.

How do I remote access my C-More EA9 HMI?

Using a web browser (Chrome), we will connect to our C-More EA9 HMI. We will then download the remote access software from the website. We will then run this remote access software to control our existing HMI program. Let’s get started. Watch the video below to see the web server and remote access in action on our C-More EA9 HMI Panel.

How do I set up remote access on the panel network?

On the C-more programming software call up the Panel Network by using the main menu | Setup | Panel Network… You could also select the panel network under Setup in the Function tab of the Navigation window. Select the Remote Access on the left-hand side of the Panel Network window.

Where can I download the C-more remote HMI app?

C-More remote HMI App can be obtained from the Apple iTunes store, Google Play or Amazon App Store for mobile devices. Here is a link to help setup the C-More remote HMI app on your mobile device. January 14, 2020 – The C-More remote HMI App is now a free download.

image

How do I connect to Cmore HMI?

0:013:51C-more HMI: Ethernet Quick Start - YouTubeYouTubeStart of suggested clipEnd of suggested clipSelect Ethernet port from the function tab. This portion is for the ethernet settings for the built-MoreSelect Ethernet port from the function tab. This portion is for the ethernet settings for the built-in port on the panel.

How do I connect my mobile to HMI?

0:114:47C-more Remote HMI: Connect Mobile App to Control your C-more HMIYouTubeStart of suggested clipEnd of suggested clipWith your c-more project open go to the panel network and then select remote access Nabal the remoteMoreWith your c-more project open go to the panel network and then select remote access Nabal the remote access feature. And this is the TCP port number that you'll be using for this connection.

How do I access HMI remotely?

Follow these five steps to remotely connect to the HMI panel of your machine from your PC or smartphone.Step 1: Connect the IXrouter to the IXON Cloud. ... Step 2: Connect your HMI panel to the IXrouter. ... Step 3: Add a VNC service. ... Step 4: Web-based access the HMI panel.More items...•

What is HMI app?

Use this Android system app to implement a distraction-optimized (DO) experience for Bluetooth calling, contact browsing, and call management.

Where is remote access window?

The Remote Access window is accessed from the Panel Network window.

What is the port number of a C-more?

The Port No. is the destination TCP port number used by the Remote Access software and the listening TCP port of the C-more panel for this connection . This will be needed for access through a Firewall/Router. Enter the Port Number. The port number must be unique for each panel on the local network when those panels are accessed from outside of that network.

How to add a tag name in a PLC?

Click on the down arrow to select a Tag Name or use the Browser button to add a new Tag Name. This tag is Off by default and can be assigned to any discrete control object in the project or in the PLC. If this tag is On, the account that is associated with it will be disabled. This means the remote user will not be able to connect using the remote access features. If this tag is activated while the remote user is connected, the connection will be dropped and the remote user will get a connection error on their PC.

What is a C-more project password?

The C-more Programming Software also has project password features that can be assigned to screens and objects to help control who can access them. These passwords are used by both the local and remote operators to restrict use to authorized personnel only. Remote users will need to know these passwords just as the local user do. There are eight group names that can be configured for passwords. For more information, click on the green Password text.

What is remote view only?

View Only: (Default for Account #1 when the remote access has been enabled.) This permission level gives the remote user the ability to only view the screen that is active on the panel (view the screen that a local operator is viewing). This can be utilized for users that are not authorized to change screens or control objects. This permission level will not interfere with the local operations of the panel. This mode could likely be used by Managers who want to monitor the machine operations for production reasons or machine status without interfering with the local operator or machine operation.

How many remote users can you have?

Each Remote Access Account can support a maximum of 5 remote user connections at a time. This allows for a maximum of 15 remote users that can be active at one time, if all three accounts are configured for the maximum setting of 5 each. Enter the number of users.

What is screen change in C-more?

View and Screen Change: Gives the remote user the ability to view and activate the “ Screen Change ” objects that are located on the active screen. This permission does not allow the remote user to activate other objects on the screen. If there are no “ Screen Change ” objects on the active screen, then remote user will not be able to change the screen. Screen Change button placement will need to be considered when the screens are created in the C-more project if the programmer wants remote users to have screen change abilities. This mode can affect the local operator if the remote user is changing screens while the local operator is using the panel.

How to remotely access Chrome?

You can set up remote access to your Mac, Windows, or Linux computer. On your computer, open Chrome. In the address bar, enter remotedesktop.google.com/access. Under “Set up Remote Access,” click Download . Follow the onscreen directions to download and install Chrome Remote Desktop.

How to access a computer remotely?

Access a computer remotely. On your computer, open Chrome. In the address bar at the top, enter remotedesktop.google.com/access, and press Enter. Click Access to select which computer you want. Enter the PIN required to access another computer. Select the arrow to connect.

How to remove a computer from Chrome?

On your computer, open Chrome. In the address bar at the top, enter remotedesktop.google.com/access, and press Enter. Next to the computer you want to remove, click Disable remote connections .

What happens if someone shares your remote access code?

If someone has shared their remote access code with you, you can remotely offer support.

How many times does the access code work?

The access code will only work one time. If you are sharing your computer, you will be asked to confirm that you want to continue to share your computer every 30 minutes.

How to end a sharing session?

To end a sharing session, click Stop Sharing. The access code will only work one time. If you are sharing your computer, you will be asked to confirm that you want to continue to share your computer every 30 minutes. Computer Android iPhone & iPad.

Is remote desktop fully encrypted?

For your security, all remote desktop sessions are fully encrypted.

How to add remote HMI file to desktop?

This is a windows based program. We can add a shortcut to this file by right-clicking the file and selecting Create shortcut. This can be then placed on your Windows desktop.

Where can I get C-More?

C-More remote HMI App can be obtained from the Apple iTunes store, Google Play or Amazon App Store for mobile devices. Here is a link to help setup the C-More remote HMI app on your mobile device.

What is a C-More HMI panel?

The C-More HMI Panel can function as a simple web server. A web server includes software and hardware that will respond to World Wide Web client requests. The communication used between client and server takes place using the Hypertext Transfer Protocol. (HTTP).

Can you control the C-More EA9?

We can now fully control our C-More EA9 HMI from this remote access window. The bottom left corner of the window will indicate that we are logged on and have full control.

Where is the connection on a C-more?

At the top, you will see CONNECTION. This is used to display the current connection you have with the C-more unit and change to a different C-more unit.

How to unlock EA9 C-more?

This can be done by pressing and holding the button while operating the HMI or double-tapping the unlock button to turn it on all of the time.

What is the Pause button on a C-more?

Pause/Play button is next on the menu. This will pause the updates from the remote c-more unit but maintains the connection.

Is the C-more remote HMI free?

We will now look at using the remote HMI app for C-more. This is available now free of charge for the Android and IOS systems.

What security measures are required for a C-more panel?

Security measures may include password protection, changing the ports exposed on your network, including a VPN in your network, and other methods. Security should always be carefully evaluated for each installation.

How far from the top of the cabinet should the touch panel be mounted?

Additional Installation Information † Clearance – The mounting clearances when installing the touch panel in an enclosure or cabinet shall be minimum of 4 inches from the top, bottom and sides and 1.72 inches from the rear. † Derating – If EA9-T15CL is mounted off the vertical plane facing upward, the temperature shall be derated as shown below. Other panels may be mounted at any angle without derating consideration.

How to access C-more panel on same router?

In order to access an additional C-more panel on the same router using the same public IP address, use a different Web server port number and Remote Access port number for each panel. (See Figure 2)

What is the second port number for remote access?

The second port number required is the Remote Access port number. The default for this application is 11102.

Do all C-more Panels have Compact Flash slots?

No. Only C-more full featured panels come with a built -in CF1 slot. –R models do not have the CF1 slot and do not support the Expansion unit required for the CF2 slot.

Do all C-more panels support standard USB memory?

Yes. The C-more panel will work with most brands of USB pen drives, provided they meet the following criteria:

What is the difference between a backup of a project and the project transferred from the C-more Software to the panel?

The project transferred to the panel, either to Internal Flash or CF1, is a “runtime” file. The panel can load this file directly to its internal volatile memory for execution. This file contains only the runtime project. The file extension is EAP.

What is the target device for a log file?

This procedure copies all log files from all memory devices to the target device. In this case, the Target Device is USB.

When is remote access memory consumed?

Memory considerations: Remote Access memory is consumed only when the remote access feature is enabled in the project and loaded to the panel. The Remote Access feature consumes memory based on the LCD resolution:

image

Accessing The Panel Server Pages

Image
Open Internet Explorer or any Internet Browsersoftware and type in the panel’s IP address. 1. No Firewall/Router: If there is no Firewall or Router between your PC and the C-more panel then type in: http://<panel IP address>:<web server port number> 2. With Firewall/Router: If there is a Firewall or Router between your PC a…
See more on automationdirect.com

Using The Remote Access Console

  • Please consider that your experience will be affected by network bandwidth and latency, as well as project screen complexity. The Remote Access Console will open and the Connection will begin. This may take several seconds based on your network speed. If the C-more Browser window does not open, it is possible that the URLthat was used is incorrect or no longer accessi…
See more on automationdirect.com

Using The Console Tool Menu

  • The Main Menu contains options that can be used or configured to enhance the Remote Access and help with performance. The Tool Barbuttons correspond to the same menu options and allow for fast access. 1. Save Image Button: Allows the remote user to save a Jpegimage to disk. This can be used to capture images of trends, alarm windows, or other screen items that may need t…
See more on automationdirect.com