Remote-access Guide

dell integrated remote access

by Dr. Milo Herman I Published 2 years ago Updated 2 years ago
image

Full Answer

What is iDRAC used for?

iDRAC (Integrated Dell Remote Access Card) configuration utility is accessed at boot time, and is useful when installing a new PowerEdge server. iDRAC alerts you when an issue occurs, enables streamlined local and remote server management, and reduces or eliminates the need for administrators to physically visit the server. Modifying iDRAC Settings

How to setup Dell iDRAC?

Symptoms

  • Turn on or reboot the managed system.
  • During Power-On Self-Test (POST), press <F2> when F2 = System Setup is displayed in the upper right corner of the screen as shown in the following figure.
  • On the System Setup Main Menu page, click iDRAC Settings, and then click Network. ...

More items...

How to access iDRAC from Windows?

  • Start Internet Explorer
  • Add your DRAC to the Compatibility View - this solves the 'undefined' menu display problem and should allow access to everything other than the Console.
  • Remove any newer versions of Java by uninstalling.

More items...

How to get iDRAC IP?

Using localcli or esxcli

  • Open the SSH service of the VMware ESXI system.
  • Log in SSH with the root account and password.
  • Run the command lines shown below to get the idrac IP address:

image

What is the difference between iLO and iDRAC?

The difference between the Both- Dell iDRAC and HP iLO: Both iLO and iDRAC support Java-based and ActiveX remote consoles. The iLO supports CLP, which is a text-based command-line interface from the DMTF while iDRAC supports skeletal command (control power, view log, exit).

What is the purpose of iDRAC?

The Integrated Dell Remote Access Controller (iDRAC) is designed for secure local and remote server management and helps IT administrators deploy, update and monitor Dell EMC PowerEdge servers anywhere, anytime.

How do I access Dell Remote Access Controller?

Access the System menu, click on the Console/Media tab and select the Virtual Console and Virtual Media option. Click on the Launch Virtual Console Button to start a remote console session. You can now use the remote console feature. Congratulations!

How do I reset my Dell Integrated remote Access Controller?

Reset using the iDRAC Settings Utility Reboot the system and press F2. In the System Setup page, click iDRAC Settings. Click Reset iDRAC configurations to default all. Click Yes to confirm, and then click Back.

Do all Dell servers have iDRAC?

Dell Remote Access Controller (iDRAC) Almost all current Dell servers have the option for an iDRAC. NOTE: IDRAC functionalities are depending of the license level. More information about licensing are available in the iDRAC User's Guide.

Is iDRAC free?

Because Dell EMC believes that none of our customers should be without the advanced remote management and automation capabilities during this difficult time, we have decided to offer a free iDRAC Enterprise 240-day Trial License*.

How do I start an iSM service?

To download the latest version of iSM:Navigate to Dell.com/support and select the server model or enter the service tag.Select Drivers & downloads.Select the Operating System for your system.Keyword iSM.Download the latest revision provided for Dell EMC iDRAC Service Module.

How do I open Dell Virtual Console?

Launching virtual console using web interfaceGo to Overview > Server > Virtual Console. The Virtual Console page is displayed. Click Launch Virtual Console. ... Go to Overview > Server > Properties. The System Summary page is displayed. Under Virtual Console Preview section, click Launch.

Is iDRAC enabled by default?

In the case of blade servers, the iDRAC network interface is disabled by default.

What is the default password for iDRAC?

In the iDRAC's default configuration, the login credentials are as follows: Username: root. Password: calvin.

How do I boot into iDRAC?

To get started, boot up your server and wait until you see the iDRAC configuration section pop up during the boot process. You'll need to quickly press CTRL + E as you only have about 5 seconds before the boot process continues. It should say Press CTRL + E for Remote Access Setup within 5 sec.

How do I reset unresponsive iDRAC?

In order to reset the iDRAC, without rebooting the operating system, press and hold the System Identification button for at 16 seconds. Stop pressing the button when the cooling fans start spinning at full speed and the front LCD (if present) is turning off. Now the iDRAC restarts without changing any saved settings.

What is iDRAC console?

The iDRAC's virtual console manages a remote system using the keyboard, video, and mouse of the management station to control the corresponding devices on a managed server. This is a licensed feature for rack and tower servers. It is available by default in blade servers.

How do I connect to iDRAC?

Turn on the managed system.Press during Power-on Self-test (POST).In the System Setup Main Menu page, click iDRAC Settings. The iDRAC Settings page is displayed.Click Network. The Network page is displayed.Specify the network settings.Click Back, click Finish, and then click Yes.

What is iDRAC module?

iDRAC Service Module (iSM) is a lightweight software OS service that better integrates operating system (OS) features with iDRAC and can be installed on Dell's 12th generation and newer PowerEdge servers.

How do I know if I have iDRAC?

Identify iDRAC version using the iDRAC Web Interface Log in to the iDRAC interface. The default iDRAC IP address 192.168. 0.120. Upon login, the version is displayed at the upper left of the iDRAC along with the iDRAC license level.

What is idrac console?

The iDRAC's virtual console manages a remote system using the keyboard, video, and mouse of the management station to control the corresponding devices on a managed server. This is a licensed feature for rack and tower servers. It is available by default in blade servers. Contact Sales team if you require an upgrade iDRAC License or to download iDRAC Trial License to enable the iDRAC virtual console for a 30 day evaluation.

How to launch a virtual console?

Go to Overview > Server > Virtual Console. The Virtual Console page is displayed. Click Launch Virtual Console. The Virtual Console Viewer is launched. Or

Does idrac need an IP address?

Before you use the iDRAC virtual console , the iDRAC must be configured with an IP address to access from your management system. For additional information, please review the iDRAC User's Guide for the specific iDRAC and firmware version as the steps vary by generation. See iDRAC Documentation

What is Dell Remote Access Controller 7?

The Integrated Dell Remote Access Controller 7 (iDRAC7) provides comprehensive, embedded management across the PowerEdge family of servers, automation that lets your organization grow, and security that ensures peace of mind. From the variety of tools and technologies in the OpenManage portfolio, you can build a management solution that matches your needs, and by leveraging iDRAC, ensures optimal server management.

How to find the service tag on Dell?

Navigate to Dell.com/support and select the server model or enter the service tag.

What is idrac white paper?

This White Paper provides information about the usage, configuration and troubleshooting of In-Band iDRAC SNMP Alerts in iDRAC Service Module v2.3 or later.

When is the idrac7 firmware release?

iDRAC7 has reached both the End of Sale as of February 2017 and End of Software Maintenance as of February 2020. The last release of iDRAC7 firmware is version 2.65.65.65.

Why is it important to extend the reach of administrators to larger numbers of distant servers?

Improved Productivity and Lower Total Cost of Ownership: Extending the reach of administrators to larger numbers of distant servers can make IT staff more productive while driving down operational costs such as travel.

Does Dell EMC require a reboot?

This ensures the best performance as well as the latest security updates and bug fixes. iDRAC updates do not require a reboot of the host, allowing for in place updates. The iDRAC7 firmware version for a server model may vary from other server models with iDRAC7. To download the latest iDRAC7 firmware for your system:

Why is Dell idrac unresponsive?

The iDRAC may become unresponsive for due to various reasons. Dell EMC recommends keeping your system up to date with the latest iDRAC firmware available . This ensures the best performance as well as the latest security updates and bug fixes. iDRAC updates do not require a reboot of the host, allowing for in place updates. The iDRAC firmware version for a server model may vary from other server models with iDRAC. To download the latest iDRAC firmware for your system:

What is idrac service module?

The iDRAC Service Module (iSM) is a lightweight software application that can be installed on PowerEdge servers running iDRAC7, iDRAC8 and iDRAC9. iSM 2.3 (and newer) allows the administrator to reset the iDRAC remotely when iDRAC is unresponsive.

How to reset idrac?

In order to reset the iDRAC, without rebooting the operating system, press and hold the System Identification button for at 16 seconds. Stop pressing the button when the cooling fans start spinning at full speed and the front LCD (if present) is turning off. Now the iDRAC restarts without changing any saved settings. It may take a minute or longer until the remote controller restarts.

What does racadm racresetcfg -rc do?

racadm racresetcfg -rc will reset all iDRAC's configuration to default, and reset the user to root/calvin.

How to find the service tag on Dell?

Navigate to Dell.com/support and select the server model or enter the service tag.

Can the administrator restart the host operating system?

Alternatively, the administrator can also restart the host operating system to resolve the issue.

Does idrac support ESXi?

On all iDRAC Service Module supported ESXi OS-es; iSM 2.3 and newer supports a CMPI method provider. This enables customers to perform the iDRAC reset remotely using WinRM remote commands. Unlike Windows (except WMI) and Linux OS-es; ESXi does not prompt the user for a confirmation before resetting the iDRAC.

Which browsers support idrac?

iDRAC is supported on the following browsers: ● Internet Explorer/Edge Mozilla Firefox Google Chrome ● Safari For the list of supported versions, see the iDRAC Release Notesavailable at https://www.dell.com/idracmanuals.

What is idrac basic?

iDRAC Basic or iDRAC Express are the standard licenses available by default on your system. iDRAC Enterprise and Datacenter licenses includes all the licensed features and can be purchased at any time. The types of upsell offered are: ● 30-day evaluation—Evaluation licenses are duration-based and the timer runs when power is applied to the system. This license cannot be extended. ● Perpetual—The license is bound to the Service Tag and is permanent. Following table lists the default license available on the following systems:

What is RAID 1?

RAID 1 is the simplest form of maintaining redundant data. In RAID 1, data is mirrored or duplicated on one or more physical disks. If a physical disk fails, data can be rebuilt using the data from the other side of the mirror. RAID 1 characteristics: ● Groups n+ ndisks as one virtual disk with the capacity ofn disks.

Is Dell a trademark?

Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. Chapter 1: Overview of iDRAC......................................................................................................16. ...

What is LC-RS in idrac8?

LC-RS provides advanced embedded systems management and is delivered as part of iDRAC8. LC-RS enables remote systems management in a one-to-many method. Remote Services uses WS-Management (WS-MAN) protocol based Web services interface to remotely provision and manage the servers.

When a passive backplane (that is not connected to PERC) is updated from the operating system,?

When a passive backplane (that is not connected to PERC) is updated from the operating system, the System Inventory page in the iDRAC Web interface does not display the updated version.

What to do if storage enclosure is disconnected?

If the storage enclosure is disconnected accidentally, reconnect it to get back to normal state. If it is intentional, perform iDRAC8 reboot or server power cycle to remove the enclosure entries from the consoles.

Does idrac apply persistence policy?

When an IO Identity Optimization Job for Network and Fibre Channel adapters is running, iDRAC does not apply persistence policy for the host power events (cold or warm reset) that occur when the job is running.

Does idrac8 display firmware?

iDRAC8 user interfaces (example, iDRAC8 Web interface, RACADM and so on) does not display the newer storage enclosure or backplane firmware version when its firmware is updated through the operating system using DUP.

Does a perc controller have a global hot spare?

If the PERC controllers have global hot spare assigned and a virtual disk is deleted, the physical disk configured as global hot spare is not reported as hot spare through the iDRAC interface. However, the physical disk continues to function as a global hot spare.

image
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9